Bathrooms and showers
Floor, wall and shower in one surface, with no grout lines to scrub.
- Waterproofing comes first. NZ Building Code clause E3 requires wet-area surfaces to be impervious and easily cleaned. Microcement and its sealer are not a substitute for a required waterproofing membrane. 8, 12
- It sits outside E3/AS1. E3/AS1 lists only three floor finishes: sheet vinyl, tiles on a continuous impervious substrate, and a steel-trowelled or polished concrete slab. A microcement floor is outside that list, so compliance has to be shown as an Alternative Solution, with test reports or an appraisal for the exact system. Whether the work needs a building consent depends on the job: ask your council (Queenstown Lakes District Council for Queenstown and Wānaka; Central Otago District Council for Cromwell and Alexandra). 11, 13
- Falls and wastes. Open showers need a fall of at least 1:50 to the floor waste within a 1.5 m radius of the shower rose. 12
- Slip. Internal house floors are assumed dry under D1/AS1, but a shower is not. BRANZ suggests an SRV of 39 (AS 4586) as good practice in bathrooms and showers, so ask for test data for the exact system. 14